Follow us as part of the AEC market for product announcements, expert information and industry updates for wall, ceiling, floor, roof and stair access products that create safer, more accessible commercial buildings.

Bookmark & Share

Posts about:

Safety

Bridging Accessibility and Sustainability: Entrance Flooring Best Practices

The Americans with Disabilities Act (ADA), enacted in 1990, remains a pivotal piece of legislation ensuring equal access and rights for people with disabilities. This comprehensive civil rights law prohibits discrimination across various sectors, including employment, public services, public accommodations, and telecommunications. A critical aspect of ADA compliance for architects and builders lies in creating accessible spaces, particularly when considering entrance flooring.

In 2010, the ADA Standards for Accessible Design set specific guidelines for public accommodations and commercial facilities. Sections 302 and 303 of the ADA highlight crucial requirements for entrance flooring to ensure safe access for all individuals, including those using wheelchairs, walkers, or other mobility aids.

View Floor Mats & Grilles

Section 302: Flooring Openings

Section 302.3 focuses on the safety and accessibility of floor openings, establishing that any gaps or openings must not exceed ½ inch in width, with the longer dimension parallel to the direction of traffic. This standard ensures that mobility aids such as wheelchairs and walkers can navigate without becoming stuck or causing accidents. Quality entrance flooring manufacturers understand this requirement and design their systems accordingly, ensuring compliance with ADA standards. The correct choice of flooring systems can prevent injuries and promote smooth transitions within a building's entrance areas.

Section 303: Changes in Level

Section 303 addresses changes in floor level, specifying that vertical transitions of ¼ inch or less are acceptable without any adjustments. However, for changes between ¼ and ½ inch, a beveled edge is required with a slope not steeper than 1 to 2. These specifications are designed to minimize tripping hazards and facilitate easy movement for individuals with mobility challenges. Changes greater than ½ inch often require a recessed solution, ensuring a seamless transition between different floor levels.

Contact a Specification Consultant

Impact on Entrance Flooring Design

Given these ADA requirements, the design of entrance flooring becomes critical for both accessibility and safety. Many entrance floor mats meet these criteria, offering a profile of ½ inch or less, often with surface-mounted beveled frames to accommodate changes in level. While some manufacturers produce ¼ inch mats, they tend to have minimal capacity for retaining dirt and debris, which may not be suitable for high-traffic areas. The recommended profile for most entrance systems is ½ inch, providing a balance between ADA compliance and effective dirt retention. Larger systems exceeding ½ inch in profile typically require recessed installation to meet ADA guidelines.

Green Building Initiatives and LEED Certification

Beyond ADA compliance, entrance flooring plays a significant role in green building initiatives and sustainable design. The green building movement, which began over two decades ago, has evolved to focus on human health and well-being. A key component of the U.S. Green Building Council's (USGBC) Leadership in Energy and Environmental Design (LEED) certification program is the reduction of indoor air pollutants. Particulate matter from burning fossil fuels and other sources can pose significant health risks when it becomes airborne. Installing effective entrance flooring systems helps trap dirt and contaminants at the building's entrance, reducing the spread of harmful particles indoors.

LEED's Indoor Air Quality credit category, specifically the Enhanced Indoor Air Quality credit, encourages the installation of entryway systems in mechanically ventilated buildings. These systems serve to capture and contain dirt, dust, and other pollutants, contributing to a healthier indoor environment. By integrating these systems into building designs, architects and builders not only meet ADA requirements but also contribute to sustainability and improved indoor air quality.

 

Ensuring compliance with ADA requirements and embracing green building initiatives are key elements in creating inclusive and sustainable spaces. The design and installation of entrance flooring systems can significantly impact accessibility and indoor air quality, contributing to the overall health and safety of building occupants. By adhering to ADA standards and supporting sustainable practices, architects and builders can create environments that are both accessible and environmentally responsible.

 Nystrom flooring systems include architectural metal grates, roll up grates, rigid grates and roll-up mats that may satisfy your building's ADA needs. For more information or product selection, please visit our website or connect with our expert Sales and Customer Support team. 

Read More

Benefits of Thermally-Broken Smoke Vents for Commercial Buildings

Enhancing Fire Safety and Energy Efficiency

In the realm of commercial building design, the integration of fire safety measures is paramount to protect occupants and property in the event of emergencies. One critical component of fire safety systems is smoke vents, which facilitate the safe evacuation of occupants and aid firefighting efforts. In recent years, thermally broken smoke vent products have emerged as innovative solutions that not only enhance fire safety but also contribute to energy efficiency and building performance. In this blog, we'll explore the benefits of thermally broken smoke vent products and their significance in commercial building design.

Read More

The Importance of Fall Protection on Commercial Floor Hatches

Safeguarding Access

Commercial floor hatches and doors provide essential access points in buildings, facilitating maintenance, equipment installation, and emergency egress. However, without adequate fall protection measures, they can pose significant safety risks to workers and occupants. In this blog post, we'll explore why fall protection is crucial on commercial floor hatches and how proper safety measures can mitigate hazards and prevent accidents.

Read More

Understanding Portable Fire Extinguishers

A Comprehensive Guide

Whether at home, in the car, boat, work or school, you’ll find fire extinguishers ubiquitous with good reason. According to the National Fire Protection Agency, code 10, the maximum travel distance to an extinguisher in a commercial building is 75 feet, emphasizing their crucial role. Knowing how to select the appropriate extinguisher is critical.

Read More

Benefits of Luminous Egress Markings

Illuminating Safety

In the realm of safety and emergency preparedness, luminous egress markings have emerged as a groundbreaking solution, revolutionizing the way we navigate buildings during low-light or emergency situations. These luminous markings, designed to glow in the dark, serve a crucial role in enhancing evacuation procedures and ensuring the safety of occupants. Let's delve into the myriad benefits that make luminous egress markings an indispensable feature in modern building design.

Read More

What's the Difference? Smoke Vent Labeling

Fire Safety Certification Differences

In the realm of fire safety, the performance and reliability of smoke vents are critical. Two of the most recognized testing and certification standards for these products are UL 793 and FM 4430. While both standards aim to ensure the effectiveness of smoke venting systems, they have distinct differences that can impact the choice of products for commercial and industrial applications. In this blog, we'll explore these variations, shedding light on the distinctions between UL 793 and FM 4430 product labeling and what it means for your fire safety strategies.

Read More

Don't Let Title 24 Trip You Up

Beyond Accessibility: Unpacking California's Title 24 and Visually Contrasting Nosings

In the intricate world of stair treads and nosings, one often hears a lot about Title 24 and its association with brightly colored nosings embedded into concrete stairs. This design choice serves a crucial purpose, making it easier for the visually impaired to identify the leading edge of a stair tread. However, there is a common misunderstanding that California Title 24 pertains solely to the accessibility aspect of the California Building Code. In reality, Title 24 encompasses a much broader spectrum, composed of 12 distinct "Parts," including the Administrative Code, Building Code, Mechanical Code, and Fire Code, among others. In essence, Title 24 represents the comprehensive California Building Standards Code, reaching far beyond accessibility considerations.

Read More

4 Effective Ways to Enhance Fall Protection for Your Roof Hatch

Securing Safe Rooftop Access

When it comes to rooftop access, safety should always be a top priority. Your commercial roof hatch, while providing essential access, can also pose significant fall hazards if not adequately protected. Fortunately, there are several ways to enhance fall protection around your roof hatch, ensuring the safety of your personnel and complying with regulatory requirements. In this blog, we'll explore four effective methods to achieve this:

Read More

Benefits of Hurricane-Tested Exterior Access Doors

Fortifying Your Building: The Advantages of Hurricane-Tested Exterior Access Doors

When it comes to commercial buildings, safety and resilience are paramount. The impact of hurricanes and severe weather events can be devastating, making it essential to fortify every aspect of the structure. One often overlooked component is the exterior access door. As the 2023 hurricane season is already active with the US experiencing three tropical storms and one hurricane since January, we'll explore the numerous benefits of Florida-Approved hurricane-tested commercial building exterior Access Doors products, highlighting why they're a game-changer for modern construction.

Read More

5 Vital Safety Products for Commercial Buildings

Ensuring Workplace Safety - How Nystrom Can Help

In today's fast-paced world, safety is a paramount concern for businesses, organizations, and individuals alike. Ensuring the well-being of everyone within a building, whether it's a workplace, commercial space, or public facility, is of utmost importance. That's where Nystrom steps in to lend a helping hand with a wide range of safety solutions designed to protect, guide, and enhance the overall safety experience.